next up previous contents
Next: MSETUP PIPELINE Up: MSETUP Previous: MSETUP CALIBRATION   Contents


MSETUP OUTPUT

        [MRTCAL\]MSETUP OUTPUT Keyword Switch

    [MRTCAL\]MSETUP OUTPUT SPECTRA YES|NO

    Indicate whether the calibration spectra should be written in the output
    CLASS file. Default is YES, i.e., write the results.

    [MRTCAL\]MSETUP OUTPUT USERSECTION YES|NO

    Indicate whether the MRTCAL user section  should  be  written  for  each
    CLASS  observation.  Default is NO, as this is very experimental to test
    future use CLASS, i.e., we do not warrants its stability.

    [MRTCAL\]MSETUP OUTPUT CHUNK ELEMENT|SET

    Write one CLASS spectra per CHUNK ELEMENT or per  CHUNKSET.  Default  is
    CHUNKSET.

    [MRTCAL\]MSETUP OUTPUT INTEGRATION CYCLE|SUBSCAN|SCAN

    Write  one  CLASS  spectra per phase cycle, or per subscan, or per scan.
    Only tracked observations are affected. On-The-Fly observations are  al-
    ways written per phase cycle. The default is SCAN.


Gildas manager 2014-07-01